fieldcommunicator

Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200

description:Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters...
BASIC INFO

Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters



 

 

General Introduction of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 
By the unique SSP (Spectral signal processing) technology, the digitalYEWFLO vortex flow meter is accurate and stable measurement of liquid, gas and steam, even in harsh process conditions. Combined with high reliability and robust design, it delivers improvements in plant efficiency and reduced operating costs. For digitalYEWFLO Multi-Variable Type (Option: /MV) built-in temperature sensor, so that temperature measurement and Mass Flow calculation is available. digitalYEWFLO Reduced Bore Type (Option: /R1, /R2) integrated and casting construction with concentric reduced bore piping.

 
Besides, Yokogawa digital YEWFLO vortex flow meter come with several outstanding features as: SSP (Spectral signal processing) technology analyses the fluid conditions inside digital YEWFLO and uses the data to automatically select the optimum adjustment forthe application, advanced self-diagnostics function, High Accuracy as ±0.75% for liquid and ±1% for gas, Wide Process Temperature Range–196°C to +450°C and etc.




Features of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 

- New functions with Spectral Signal Processing (SSP) technology SSP analyses the fluid conditions inside the digitalYEWFLO vortex flowmeter and uses the data to automatically select the optimum adjustment for the application, providing features never seen before in a vortex flowmeter.
SSP accurately senses vortices in the low flow range, providing outstanding flow stability.

- Advanced self-diagnostics
Application conditions such as high pipeline vibration and abnormal flow are predicted and indicated.

- High accuracy
±0.75% of reading (liquid)
±1.0% of reading (gas, steam)

- Wide process temperature range
High temperature version up to 450 deg C
Cryogenic version minimum -196 deg C

- Simple parameter settings
Frequently-used selections grouped together in a quick-access format decrease commissioning time

- Clear, concise indicator
Convenient display of the simultaneous and total flow rates together with the process diagnosis

- Dual output for analog/pulse
Simultaneous output for flow rate and pulse

- Alarm output
An alarm signal is output when an alarm occurs.

- BRAIN/HART communication and key switches for human-machine interface
- NACE compliant
- NAMUR 43 compliant
- Remote cable length up to 30m

 

 

Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 

The world's first two-wire Multi-variable Type (with built-in temperature sensor) can directly output the mass flow rate of saturated steam.

 

The digitalYEWFLO vortex flowmeter combines the field proven sensor and body assembly used in more than 260,000 units installed worldwide with a unique and powerful combination of digital technology that includes spectral signal processing (SSP), a Yokogawa innovation. The digitalYEWFLO vortex flowmeter is accurate and stable, even in harsh process conditions, and has a highly reliable and robust design that delivers improvements in plant efficiency and reduced operating costs.

 

Specification of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 

 

Standard Type

Reduced Bore Type

Multi-Variable Type

Model

Model DY
Vortex Flow meter
(Integral Type,
Remote Type)
Model DYA
Vortex Flow Converter
(Remote Type)
(Option for High
Process Temperature
Version: /HT,
Option for Cryogenic Version: /LT)

Option: /R1, /R2
1 size down: /R1
2 size down: /R2
(Option for High
Process Temperature
Version: /HT)

Option: /MV

Fluid to be Measured

Liquid, Gas, Steam (Avoid Multiphase Flow and Sticky Fluids)

Nominal Size

Wafer

15 to 100 mm

N/A

25 to 100 mm

Flange

15 to 400 mm

R1: 25 to 200 mm
(Detector: 15 to 150 mm)
R2: 40 to 200 mm
(Detector: 15 to 100 mm)

25 to 200 mm
(Special: 250 to 300 mm)

Accuracy

Liquid

±0.75% of Reading
(Depends on Reynolds number)

±1.0% of Reading
(Depends on Reynolds number)

±0.75% of Reading
(Depends on Reynolds number)

Gas
Steam

±1.0% of Reading
(Depends on flow velocity)

Output Signal

Dual Output (Both analog and pulse output available)
Communication: HART 5/HART 7, BRAIN, FOUNDATION™ fieldbus

Process Temperature

-29 to 250 deg C
-29 to 450 deg C (/HT)
-196 to 100 deg C (/LT)

-29 to 250 deg C
-29 to 450 deg C (/HT)

-29 to 250 deg C
-29 to 400 deg C (/HT)

Process Pressure

-0.1MPa (-1kg/cm2) to flange rating

Ambient Temperature

-29 to 85 deg C (Depends on model type)

Ambient Humidity

5 to 100% RH (No Condensation)

Mounting

Flange or Wafer Type
JIS 10/20/40K
ANSI 150/300/600/900
(Special: 1500)
DIN PN 10/16/25/40/
60/100/160

Flange Type only
JIS 10/20K
ANSI 150/300

Flange or Wafer Type
JIS 10/20/40K
ANSI 150/300/600/
900
DIN PN 10/16/25/40

Electrical Connection

JIS G1/2 Female, ANSI 1/2NPT Female, ISO M20×1.5 Female

Explosion Protected Type

TIIS Ex d, FM Ex d/Ex ia, ATEX Ex d/Ex ia,
CSA Ex d/Ex ia, IECEx Ex d, SAA Ex ia

Material

Body: Stainless steel(Special: Hastelloy, Carbon steel)
Shedder Bar: Duplex stainless steel(Option: Stainless steel, Hastelloy)
Gasket: Stainless steel with Teflon coating (/HT: with Silver plating)
Converter housing, case and cover: Aluminum alloy(Option: Stainless steel)

 

Range of measurable water flow rate at standard condition  Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
 

Model Code

Measurable Flow Rate

(m3/h)

Range of Fixed Accuracy Flow Rate

( m3/h)

DY015

DY025/R1

DY040/R2

0.30 to 6

0.94 to 6

DY025

DY040/R1

DY050/R2

0.65 to 18

1.7 to 18

DY040

DY050/R1

DY080/R2

1.3 to 44

2.6 to 44

DY050

DY080/R1

DY100/R2

2.2 to 73

3.3 to 73

DY080

DY100/R1

DY150/R2

4.3 to 142

4.6 to 142

DY100

DY150/R1

DY200/R2

7.5 to 248

7.5 to 248

DY150

DY200/R1

17 to 544

18 to 544

DY200

34 to 973

34 to 973

DY250

60 to 1506

60 to 1506

DY300

86 to 2156

86 to 2156

DY400

177 to 3547

177 to 3547


 

Model selection and suffix codes of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
 

Model

Suffix Codes

Description

DY015

           

Size 15 mm (1/2 inch)

DY025

           

Size 25 mm (1 inch)

DY040

           

Size 40 mm (1-1/2 inch)

DY050

           

Size 50 mm (2 inch)

DY080

           

Size 80 mm (3 inch)

DY100

           

Size 100 mm (4 inch)

DY150

           

Size 150 mm (6 inch)

DY200

           

Size 200 mm (8 inch)

DY250

           

Size 250 mm (10 inch)

DY300

           

Size 300 mm (12 inch)

DY400

           

Size 400 mm (16 inch)

Output Signal and

Communication

-D

         

4 to 20mA DC Output Pulse, BRAIN   Communication

-E

         

4 to 20 mA DC Output Pulse, HART   Communication

-J

         

4 to 20 mA DC, Pulse, HART 5/HART 7 Communication

-F

         

Digital communication, (FOUNDATION Fieldbus protocol)

-N

         

Remote type detector

Body Material

 

A

       

SCS14 A

 

B

       

CF8M

 

X

       

Others

Shedder bar Material

   

L

     

Duplex Stainless Steel

   

B

     

Stainless Steel

   

E

     

Duplex Stainless Steel (for TIIS   Approval)

   

X

     

Others

Process Connection

     

AJ1

   

JIS 10 K Wafer

     

AJ2

   

JIS 20 K Wafer

     

AJ4

   

JIS 40 K Wafer

     

AA1

   

ANSI Class 150   Wafer

     

AA2

   

ANSI Class 300   Wafer

     

AA4

   

ANSI Class 600   Wafer

     

AD1

   

DIN PN10 Wafer

     

AD2

   

DIN PN16 Wafer

     

AD3

   

DIN PN25 Wafer

     

AD4

   

DIN PN40 Wafer

     

BJ1

   

JIS 10K   Flange(RF)

     

BJ2

   

JIS 20K   Flange(RF)

     

BJ4

   

JIS 40K   Flange(RF)

     

BA1

   

ANSI Class 150   Flange(RF)

     

BA2

   

ANSI Class 300   Flange(RF)

     

BA4

   

ANSI Class 600   Flange(RF)

     

BA5

   

ANSI Class 900   Flange(RF)

     

BS1

   

ANSI Class 150   Flange(RF, SF)

     

BS2

   

ANSI Class 300   Flange(RF, SF)

     

BS4

   

ANSI Class 600   Flange(RF, SF)

     

BS5

   

ANSI Class 900   Flange(RF, SF)

     

BD1

   

DIN PN10   Flange(RF)

     

BD2

   

DIN PN16   Flange(RF)

     

BD3

   

DIN PN25   Flange(RF)

     

BD4

   

DIN PN40   Flange(RF)

     

CA4

   

ANSI Class 600   Flange(RJ)

     

CA5

   

ANSI Class 900   Flange(RJ)

     

FD1

   

DIN PN10 Flange(R13)

     

FD2

   

DIN PN16   Flange(R13)

     

FD3

   

DIN PN25   Flange(R13)

     

FD4

   

DIN PN40   Flange(R13)

Electrical Connection

       

-0

 

JIS G1/2 female

       

-2

 

ANSI 1/2 NPT   female

       

-4

 

ISO M20*1.5   female

Indicator

         

D

With Indicator

         

N

None Indicator, Remote type detector

Optional codes

/Optional codes

 

Model selection of vortex flowmeter remote converter     Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
 

Model

Suffix Codes

Description

DYA

     

Vortex Flowmeter Converter (Remote   Type)

Output Signal and Communication

-D

   

4 to 20mA DC Output Pulse, BRAIN   Communication

-E

   

4 to 20 mA DC Output Pulse, HART   Communication

-J

   

4 to 20 mA DC, Pulse, HART 5/HART 7 Communication

-F

   

Digital communication, (FOUNDATION Fieldbus protocol)

Electrical Connections

 

0

 

JIS G1/2 Female

 

2

 

ASME 1/2 NPT   Female

 

4

 

ISO M20×1.5   Female

Indicator

   

D 

With Indicator

   

N

None Indicator

Optional codes

/Optional codes

 

Model selection of signal cable for remote transmitter   Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
 

 

Model

Suffix Codes

Description

DYC

     

Signal Cable

Cable End

-0

   

Without End finish

-1

   

With End finish

Cable Length

 

-##

 

Designate the cable length, 5 to 95m

Option

   

/C#

With termination parts sets

 

 

 

 

Ordering Number of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 

DY Vortex Flowmeter(Integral Type, Remote type detector):

DY015-DALAA1-2D

DY025-EALAJ2-0D

DY040-EALAD4-4D

DY050-EBLBJ4-2N

DY080-JALBA5-4N

DY100-JBLBS1-4N

DY150-FALBD2-2D

DY200-EBECA4-2N

DY250-DBLAD2-4D

DY300-DBLAA2-2D

 

Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters

 

DYA Vortex Flowmeter Converter(Remount type)

DYA-D2D

DYA-E2D

DYA-D0D

DYA-D0N

DYA-E0N

DYA-E0D

DYA-D4D

DYA-E4D

DYA-D4N

DYA-E4N

DYA-D2N

DYA-E2N

DYC Signal Cable:

DYC-0-05/C1/MV

Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters


 

 

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply 
Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.

 
Why do you choose us?
 
1. 100% original brand product, 100% quality assurance.
    If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send  you a new product asking zero cent.
 
2. Varied payment methods.
    We adopt L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
Packaging: Imported with original packaging or standard export packing.Customize design is acceptable.
 
Shipping: By Express(EMS,DHL,UPS,TNT, FEDEX, ARAMEX), By Air, By Sea.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)

Previous:Yokogawa YTA610-JA1A2DD/SG YTA610 Field Mount Temperature Tr Next:Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyze